Make: Zenotrex Medico
Model: ZPL-A22R
Model: ZPL-A22R
VERTICAL AUTOCLAVE FULLY AUTOMATIC
Vertical autoclaves are also known as top loading sterilizers that come in cylindrical shape. The working of vertical autoclave is simple to understand; to open, a radial locking mechanism is fitted at top of the lid; a foot lever (pedal) is attached at the bottom. User has to press the pedal and lift the lid. Vertically designed chamber provides guaranty of safe and efficient sterilization even in confined spaces.
FEATURES:
- Capacity:- 20-150 Liters
- Equipped with joint less silicon rubber gaskets
- Simple and Easy to load and unload
- Completely Digital monitorable, microprocessor-controlled One-touch operation, constant management and monitoring of autoclave functions and parameters
- Steam collection bottles to remove most of the steam during operation.
- Ware inlet and outlet valve with inbuilt
- Drain valve for cleaning or changing with fresh water
- Constructed with appropriate stainless steel with superior corrosion resistance to water and steam
- High temperature and pressure resistant silicon gasket
- Start-timer setting range: 1-99 hours in each operation mode
- Floor mounted & self stand.
- Preset timer: atleast upto 9 hours.
- A water level gauge. Analog gauges for measuring inner and outer steam pressure.
- PT100 type temperature sensor.
SPECIFICATIONS:
Working Pressure & gauge |
Variable 15- 20 PSI(0-127kPa) with Analog Pressure Gauge(Maximum Pressure: 147 kPa) (Optional 4bar) |
Working Temperature |
100°C to 140°C(Facility of warming temp range 40°C to 60°C and Dissolving Temperature range 40°C to 100°C.) |
Internal Chamber |
304/316 SS |
External Chamber |
Mild Steel (304 stainless Steel – Optional) |
Door |
Foot lifted with safety and interlock device stainless steel sheet of 304 grade (min.5 mm thickness) Radial locking type. Elastomeric rubber gasket suitable to withstand temperature upto 140°C and pressure upto 2 bar. |
Insulation |
Glass wool insulation |
Heating device (steam generator) |
inside the jacket made up of heavy gauge stainless steel, separated from the chamber with upto 60°C to 150°C drying temperature. |
Sterilization Period |
25 to 30 Minutes |
Time display Range |
a. Sterilizing Mode: 1-240 minutes or continuous b. Sterilizing-warming mode: 1-240 minutes (sterilizing)/48 hours (warming) c. Heating mode: 1-8 hours d. dissolving time upto 48 hours |
LED display |
LED display for temperature and remaining time |
Power Supply |
220-240 Volts, 50/60 Hz, single phase |
Additional Feature
Leakage breaker: |
a. Rated breaking current: 20A (120V), 15A (220/230/240V) b. Rated sensed current: 30mA (120V), 10mA (220/230/240V) |
Safety and Malfunction prevention device |
|
Operating Environment |
a. Ambient temperature range: 5 – 35 °C
|